USING  THE EXTRA SPACE  COMMAND

     
     The Extra Space command ( ES ), adjusts space between
     characters and lines of labels without affecting
     character size. For more information see the PCL 5
     Printer Language Technical Reference Manual. The syntax
     for this command is as follows:
     
     ES width,[height]; or ES;

PARAMETERS:
     
     Width                         Specifies an increase
                                   (positive number) or
                                   decrease (negative
                                   number) in the space
                                   between characters.
     
     Height                        Specifies an increase
                                   (positive number) or
                                   decrease (negative
                                   number) in the space
                                   between lines.
     

PROGRAM:
     
     LEGEND: Ec = [Ctrl] [P] [Esc] in DOS EDIT.
     
     
     
     
     EcE                           Resets the printer.
     
     Ec%0B                         Enters HP-GL/2 mode.
     
     IN;                           Initializes HP-GL/2 mode.
     
     SP1;                          Selects pen number 1,
                                   (black). Even though
                                   there is no physical pen,
                                   the SP command must be
                                   used to enable printing.
     
     PA2500,3200;SI.187,.269;      Specifies absolute
                                   plotting and moves to
                                   (2500,3200); specifies a
                                   relative character size
                                   of .187 cm wide by .269
                                   cm high.
     
     DT#;ES;                       Defines the "#" character
                                   as the label terminator
                                   and sets the extra space
                                   setting to default (no
                                   extra spaces).
     
     LBES; CAUSES#;                Prints "ES; CAUSES".
     
     CP;LBTHIS SPACING.#;          Sends a CP command with
                                   no parameters, which is
                                   equivalent to a Carriage
                                   Return and Line Feed;
                                   prints "THIS SPACING.".
     
     PA2500,2500;                  Moves to (2500,2500).
     
     ES-.1,-.25;LBES-.1,-.25; CAUSES#;  Decreases the inter-
                                   character spacing by .1
                                   and the inter-line
                                   spacing by .25; prints
                                   "ES-.1,-.25; CAUSES".
     
     CP;LBTHIS SPACING#;           Sends a CP command with
                                   no parameters, which is
                                   equivalent to a Carriage
                                   Return and Line Feed;
                                   prints "THIS SPACING".
     
     PA2500,1800;                  Moves to (2500,1800).
     
     ES.2,.25;LBES.2,.25; CAUSES#; Increases the inter-
                                   character spacing by .2
                                   and the inter-line
                                   spacing by .25. Then
                                   prints "ES.2,.25;
                                   CAUSES".
     
     CP;LBTHIS SPACING#;           Sends a CP command with
                                   no parameters, which is
                                   equivalent to a Carriage
                                   Return and Line Feed.
                                   Then prints "THIS
                                   SPACING.".
     
     Ec%0A                         Enters PCL mode.
     
     EcE                           Sends a reset to end the
                                   job and eject the page.






            Copyright  Hewlett-Packard Co. 1993
   The information contained herein is subject to change
                      without notice.
   Hewlett-Packard shall not be liable for incidental or
  consequential damages in connection with the use of this
                         material.



file: /Techref/language/pcl/lj2022.asc, 4KB, , updated: 1993/11/15 16:23, local time: 2012/2/9 09:17,
TOP NEW HELP FIND: 
38.107.179.232:LOG IN

 ©2012 These pages are served without commercial sponsorship. (No popup ads, etc...).Bandwidth abuse increases hosting cost forcing sponsorship or shutdown. This server aggressively defends against automated copying for any reason including offline viewing, duplication, etc... Please respect this requirement and DO NOT RIP THIS SITE. Questions?
Please DO link to this page! Digg it! / MAKE! / 

<A HREF="http://www.piclist.com/techref/language/pcl/lj2022.asc"> language pcl lj2022</A>

Did you find what you needed?

 
SX MASTERS: Eric Smith and Richard Ottosen's SERVID is an intellegent RS232 video terminal (4x20 character display) in one SX chip. See the write up.
 
miSim DE is an excellent, portable and powerful IDE for developing PIC applications.
The only consistant, simple to use yet powerful development environment. It simulates real-world devices via virtual component "plugins" (LED,LCD,key,motor,TV,etc) in real time, has a syntax highlighting editor, macro assembler and disassembler. Regular updates and third-party plugins keep this software ahead of any other PIC IDE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

  .