piclist 2008\07\21\080042a >
Thread: Eagle ERC questions
www.piclist.com/techref/pcbs.htm?key=eagle
face picon face BY : email (remove spam text)(Olin Lathrop)



> SUPPLY pin GND overwritten with more than one signal(H-GND,
> GND)

Eagle thinks the name of the net connected to a supply pin should be the
same as the name of the supply pin.  I think that's a silly rule and makes
the ERC less useful, but there is no way to shut it off that I know of.  You
just have to go thru all ERC warnings and make sure none of them are "real".


********************************************************************
Embed Inc, Littleton Massachusetts, http://www.embedinc.com/products
(978) 742-9014.  Gold level PIC consultants since 2000.
<013d01c8eb29$aa2e32c0$0300a8c0@main> 7bit

See also: www.piclist.com/techref/pcbs.htm?key=eagle