piclist 2001\09\27\225030a >
Thread: Low Voltage AC Dimming and Reverse Phase Control
www.piclist.com/techref/power.htm?key=voltage
flavicon
face BY : Michael C. Reid email (remove spam text)



I am in the lighting control industry and our triac and dual scr dimmers are
used to dim 12 and 24 VAC light via transformers all the time.  All you have
to do is take into account the loss associate with the tranformer and the
high inrush current when turing on the transformer.  Most triac dimmers are
set up to drive inductive loads without any problem.

{Original Message removed}
<MABBLFMMFGEFGEJCLDJBCECPCOAA.mikecreid@qwest.net> 7bit

In reply to: <3BB3D748.BF3870E2@3mtmp.com>
See also: www.piclist.com/techref/power.htm?key=voltage
Reply You must be a member of the piclist mailing list (not only a www.piclist.com member) to post to the piclist. This form requires JavaScript and a browser/email client that can handle form mailto: posts.
Subject (change) Low Voltage AC Dimming and Reverse Phase Control

month overview.