Searching \ for 'loadcell' in subject line. ()
Make payments with PayPal - it's fast, free and secure! Help us get a faster server
FAQ page: www.piclist.com/techref/io/atod.htm?key=adc
Search entire site for: 'loadcell'.

Truncated match.
PICList Thread
'loadcell'
1998\07\15@201651 by Tan Cheow Beng

flavicon
face
Anyone know the best way to connect the loadcell to pic and have any one
done with it.?
I try to connect it to an AD/DC 12bit with PIc 16f84 and I need to know any
routine available?.
Thank you.
From:Tan Cheow Beng
email: spam_OUTbemlab5TakeThisOuTspamnus.sg

1998\07\16@052706 by Octavio Nogueira

flavicon
face
The best way to do this is to use the Analog-Device AD7714/AD7715/AD7730
You don't even need an amplifier.

Regards,

Octavio
======================================================
Octavio Nogueira  - e-mail:   .....nogueiraKILLspamspam@spam@mandic.com.br
http://www.geocities.com/~oct_nogueira
"ProPic" Production PIC Programmer Windows under US$20
======================================================
-----Mensagem original-----
De: Tan Cheow Beng <bemlab5spamKILLspamLEONIS.NUS.EDU.SG>
Para: .....PICLISTKILLspamspam.....MITVMA.MIT.EDU <EraseMEPICLISTspam_OUTspamTakeThisOuTMITVMA.MIT.EDU>
Data: Quarta-feira, Julho 15, 1998 09:13
Assunto: loadcell


>Anyone know the best way to connect the loadcell to pic and have any one
>done with it.?
>I try to connect it to an AD/DC 12bit with PIc 16f84 and I need to know any
>routine available?.
>Thank you.
>From:Tan Cheow Beng
>email: bemlab5spamspam_OUTnus.sg
>

1998\07\16@081454 by WF AUTOMACAO

flavicon
face
Tan Cheow Beng wrote:
>
> Anyone know the best way to connect the loadcell to pic and have any one
> done with it.?
> I try to connect it to an AD/DC 12bit with PIc 16f84 and I need to know any
> routine available?.
> Thank you.
> From:Tan Cheow Beng
> email: @spam@bemlab5KILLspamspamnus.sg

See I2C A/D (I think that Harris Has)!

Miguel.

1998\07\16@081656 by Morgan Olsson

picon face
At 08:07 1998-07-16 +0800, you wrote:
>Anyone know the best way to connect the loadcell to pic and have any one
>done with it.?

Right now I«m using PIC14000 with a LP324 preamp.
Works, but not very fun.
Seem to be lot of noise, especially in PIC14000 internal ramp comparator
(even tested with stabel input, large cap and CPU in sleep), and needs
routines to calibrate continously, both PIC14000 A/D function, and preamp
drift.

I will ship it as is for now, and redesign with Maxim multislope converter
instead.  Will probably not even need preamp, and no compensation for
anything!

Much better but more expensive...

/Morgan
/  Morgan Olsson, MORGANS REGLERTEKNIK, SE-277 35 KIVIK, Sweden \
\  KILLspammrtKILLspamspaminame.com, ph: +46 (0)414 70741; fax +46 (0)414 70331    /