> Speaking of one-wire devices......
>
> Does anyone here have any idea as to what the maximum cabling
length
> can be, between the controller (16F877) and the device (DS18S20)?
>
Larry,
It depends upon the cable type you use.
From application note 132:
For up to 5m the cable type is non-critical.
Regular UTP is good for 25m
Cat-3 is good for up to 125m
Cat-5 is good up to 300m
With specialized line drivers Dallas claims you can go to 600m