2008\07\28@052353 by Chetn/a

flavicon
face
In SX Microcontrollers, SX/B Compiler and SX-Key Tool, Chet wrote:

How do you read the ID field from the SX?  
Do you have to write into the program to disply it or is there another way to check it?


Thanks

Chet
---------- End of Message ----------

You can view the post on-line at:
http://forums.parallax.com/forums/default.aspx?f=7&p=1&m=281771
Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com
The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2008 (http://www.dotNetBB.com)

2008\07\28@150206 by Zootn/a

flavicon
face
In SX Microcontrollers, SX/B Compiler and SX-Key Tool, Zoot wrote:

With the SX-Key connected:

Run -> Device -> Read
The ID will show up in the ID field middle right; if the chip is not "copy-protected" then the source (hex) will appear in the field at lower left (code can be saved to desktop). Even if copy protected, the 8 byte (character) ID can still be read.

---------- End of Message ----------

You can view the post on-line at:
http://forums.parallax.com/forums/default.aspx?f=7&p=1&m=281771#m281870
Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com
The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2008 (http://www.dotNetBB.com)

2008\07\28@153658 by g_daubachn/a

flavicon
face
In SX Microcontrollers, SX/B Compiler and SX-Key Tool, g_daubach wrote:

Chet,
the ID field is "for reference only" - IOW you may assign a string of text to it with the "ID" directive in a souce code file, and you may later retrieve it like Zoot had described it. There is no way to directly read the ID string from within an SX application program.

---------- End of Message ----------

You can view the post on-line at:
http://forums.parallax.com/forums/default.aspx?f=7&p=1&m=281771#m281879
Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com
The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2008 (http://www.dotNetBB.com)

2008\07\28@153937 by JonnyMacn/a

flavicon
face
In SX Microcontrollers, SX/B Compiler and SX-Key Tool, JonnyMac wrote:

If you need to retrieve an ID at run time you can always store it in a table and read it out.  Since data in the SX can only be changed at programming time there is no [/littel] danger of the ID becoming corrupt.

---------- End of Message ----------

You can view the post on-line at:
http://forums.parallax.com/forums/default.aspx?f=7&p=1&m=281771#m281880
Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com
The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2008 (http://www.dotNetBB.com)

2008\07\28@214559 by Chetn/a

flavicon
face
In SX Microcontrollers, SX/B Compiler and SX-Key Tool, Chet wrote:

Thanks gents.  I will give it a try tomorrow.

Chet
---------- End of Message ----------

You can view the post on-line at:
http://forums.parallax.com/forums/default.aspx?f=7&p=1&m=281771#m281926
Need assistance? Send an email to the Forum Administrator at forumadmin@parallax.com
The Parallax Forums are powered by dotNetBB Forums, copyright 2002-2008 (http://www.dotNetBB.com)

More... (looser matching)
- Last day of these posts
- In 2008 , 2009 only
- Today
- New search...