Searching \ for '[PIC]: ICD-2 tales, part 002' in subject line. ()
Make payments with PayPal - it's fast, free and secure! Help us get a faster server
FAQ page: www.piclist.com/techref/microchip/devprogs.htm?key=icd
Search entire site for: 'ICD-2 tales, part 002'.

Exact match. Not showing close matches.
PICList Thread
'[PIC]: ICD-2 tales, part 002'
2002\04\26@213033 by Barry Gershenfeld

picon face
Forgot the PIC tag.  And you wonder how I can get this stuff
to work.  Sorry for the duplicate.

It feels as though I am blazing new territory.  And now that I
hear the 18F252's are only available as samples, that sounds
about right.  Anyway I have made the following observations
so far, with the ICD-2.   Since it's still not working, I'm
not sure if any of this would change once whatever it is, is
fixed.

If I disconnect the cable from the target, and try to program
the target, it programs it anyway.  That is, the programming
pass is apparently write-only.  So, as they say, "no errors
are possible".   On the verify pass, it says the the target
doesn't match the code.  That's a little closer, but it still
doesn't realize it's talking to "air".    Not until it tries
to talk to the debug innards does it realize no one's there
and time out (but it does that even when hooked up.)   I would
suspect it of not reading at all except that it will verify
a program that's put in without debug enabled.

Another odd behavior is with the clock.  The '252 gets a 7 MHz
clock on OSC1, and I check OSC2 with various oscillator
configurations.  With HS I see the signal on OSC2 although
it's had all the high frequencies removed.  With RC, XT, and
LP, nothing comes out that pin.  I have subsequently discovered
more settings for this chip.  Of particular interest is
"external" (which is actually the obvious choice) with the
clock/4 available on OSC2.  That doesn't work.  I keep hoping
to find some detectable signs of life on that thing.

Bad chip?  Lo and behold we had another board.  Same behavior.
Bad cable?  I tried the one off my ICD-1 and it's the same.
Bad ICD-2?  Well, I hate to blame it on bad parts but at some
point you just have to try.  We're getting another ICD-2 next
week sometime.

I'm still expecting to find some kind of default automatic
sleep-on-hardware feature here but theoretically this chip
is a spittin' image of the 16F876 that we were using before.

Oh, I did wave a dead fish over it.  No correlation.

Thanks for listening.

Barry

--
http://www.piclist.com hint: To leave the PICList
spam_OUTpiclist-unsubscribe-requestTakeThisOuTspammitvma.mit.edu