As stated in an earlier post, I'm creating software for a old Radio Shack
Probescope using Softwire and VB6. The softwire serial control is giving me
problems. It recieves the serial stream but terminates the output string
after a null char even though I have it set to recieve 280 bytes with no
termination char. So I end up with varying size peices of string. Any thing
to stop this. Thanks.
Matt
2005\01\12@152237
by
Bruce
> As stated in an earlier post, I'm creating software for a old Radio Shack
> Probescope using Softwire and VB6. The softwire serial control is giving me
> problems. It recieves the serial stream but terminates the output string
> after a null char even though I have it set to recieve 280 bytes with no
> termination char. So I end up with varying size peices of string. Any thing
> to stop this. Thanks.
>
> Matt
I had the same problem. Ended up tying a timer to the SoftWire serial control
input to ping it & keep it alive. Worked great on everything except XP systems.
Eventually ended up just tossing the VB6 MSComm control on the form, and
using that. Now it works on everything. I have the full source code on our site
here: http://www.rentron.com/PicBasic/AD_Log.htm for an A/D data logger with
strip chart, analog V meter, etc,, using SoftWire/VB6. You're welcome to it.
HTH
-Bruce
http://www.rentron.com