Exact match. Not showing close matches.
PICList
Thread
'[EE] Eagle question (also relevant to pic)'
2006\03\07@190037
by
Will
Hi,
I want to use Eagle to draw my schematic. When ever I need to connect to
a signal, for example GND, I want to place the GND as close as possible
to the component, like in the schematics from microchip. This means that
I need to be able to have many GND symbols but that they should all
be the same net. Aparently Eagle does not let me do this. Is this right?
Will
2006\03\07@192135
by
Josh Koffman
On 3/7/06, Will <spam_OUTkerri1111111TakeThisOuT
btinternet.com> wrote:
> I want to use Eagle to draw my schematic. When ever I need to connect to
> a signal, for example GND, I want to place the GND as close as possible
> to the component, like in the schematics from microchip. This means that
> I need to be able to have many GND symbols but that they should all
> be the same net. Aparently Eagle does not let me do this. Is this right?
No, this is incorrect. With Eagle, as long as your nets have the same
name, they are connected, even if you don't draw a line representing
that. If your put in multiple ground symbols ensure that they have the
same net names. Then when you generate a board they should all show as
connected.
Josh
--
A common mistake that people make when trying to design something
completely foolproof is to underestimate the ingenuity of complete
fools.
-Douglas Adams
2006\03\07@204409
by
Will
> > I want to use Eagle to draw my schematic. When ever I need to connect to
> > a signal, for example GND, I want to place the GND as close as possible
> > to the component, like in the schematics from microchip. This means that
> > I need to be able to have many GND symbols but that they should all
> > be the same net. Aparently Eagle does not let me do this. Is this right?
>
> No, this is incorrect. With Eagle, as long as your nets have the same
> name, they are connected, even if you don't draw a line representing
> that. If your put in multiple ground symbols ensure that they have the
> same net names. Then when you generate a board they should all show as
> connected.
I tried to add two gnd's, then eagle names them gnd1 and gnd2. If I try to
rename gnd2 to gnd1 it doesn't allow that?
2006\03\07@223720
by
Josh Koffman
On 3/7/06, Will <.....kerri1111111KILLspam
@spam@btinternet.com> wrote:
> I tried to add two gnd's, then eagle names them gnd1 and gnd2. If I try to
> rename gnd2 to gnd1 it doesn't allow that?
Then you're likely trying to change the name of the ground symbol. You
need to change the name of the net by clicking on a wire not the
symbol.
Josh
--
A common mistake that people make when trying to design something
completely foolproof is to underestimate the ingenuity of complete
fools.
-Douglas Adams
2006\03\08@070959
by
olin piclist
Will wrote:
> I want to use Eagle to draw my schematic. When ever I need to connect to
> a signal, for example GND, I want to place the GND as close as possible
> to the component, like in the schematics from microchip. This means that
> I need to be able to have many GND symbols but that they should all
> be the same net. Aparently Eagle does not let me do this. Is this right?
No. Eagle most certainly lets you do this.
******************************************************************
Embed Inc, Littleton Massachusetts, (978) 742-9014. #1 PIC
consultant in 2004 program year. http://www.embedinc.com/products
2006\03\08@073624
by
olin piclist
Will wrote:
> I tried to add two gnd's, then eagle names them gnd1 and gnd2. If I try
> to rename gnd2 to gnd1 it doesn't allow that?
Your ground symbols are incorrectly made. Go to
http://www.embedinc.com/pic/dload.htm and install the Eagle tools release.
After installation you will find proper ground symbols in
eagle/lib/Power.lib.
******************************************************************
Embed Inc, Littleton Massachusetts, (978) 742-9014. #1 PIC
consultant in 2004 program year. http://www.embedinc.com/products
2006\03\08@082230
by
Will
> > I tried to add two gnd's, then eagle names them gnd1 and gnd2. If I try
> > to rename gnd2 to gnd1 it doesn't allow that?
>
> Your ground symbols are incorrectly made. Go to
> http://www.embedinc.com/pic/dload.htm and install the Eagle tools release.
> After installation you will find proper ground symbols in
> eagle/lib/Power.lib.
No, my gnd symbols are ok, someone suggested to rename the net rather
than the symbol, and it DID work this time, so it seems to be what I need.
2006\03\08@082800
by
olin piclist
Will wrote:
> No, my gnd symbols are ok, someone suggested to rename the net rather
> than the symbol, and it DID work this time, so it seems to be what I
> need.
If you use proper ground symbols they will automatically name the net for
you. You shouldn't be manually renaming nets when using ground symbols.
******************************************************************
Embed Inc, Littleton Massachusetts, (978) 742-9014. #1 PIC
consultant in 2004 program year. http://www.embedinc.com/products
More... (looser matching)
- Last day of these posts
- In 2006
, 2007 only
- Today
- New search...